OPC
3.6 OPC
3.6.1 OPC BELT UNIT
CAUTION: Do not touch the OPC belt. Hold the grip [F] when you move the OPC
belt unit.
1. Open the scanner unit [A].
[B]
2. Open the center cover [B].
[A]
3. Release the locks [C] [D].
[C]
[D]
G157R569.WMF
4. OPC belt unit [E]
Necessary Setting
[F]
You must do the "CARED BL UNIT ?"
procedure after you replace the OPC belt
[E]
unit. (
5.1.2 SERVICE MODE
FUNCTIONS: "SERVICE MODE" >
"CLEAR CARE" > "CARED BL UNIT ?")
G157R570.WMFFF
G157
3-18
SM