Code 44 LIFE PERIOD SET

You can set the replacement interval for the PM parts.
NOTE: Do not use in the field.
1. Select "LIFE PERIOD SET" in the "FACTORY
MODE" using the "Scroll" key.
2. Press the "Select" key.
3. Select one of the following codes using the "Scroll"
key, and then press the "Select" key.
1~6, B, C, F, G: Not used
7: Belt Cartridge (BL)
8: Fusing Unit (FU)
9: Drum Cleaner/ Transfer Roller (TR)
A: Transfer Belt (120K)
D: Paper Feed Roller (PICK ROL)
E: Paper Feed Roller (PICK LFU)
4. Use the "Scroll" key to move the cursor, and use the
"Select" key to input a value at the blinking digit.
NOTE: The minimum adjustable value is 100p.
5. Use the" Scroll" key to move the cursor to "SET",
and then press the "Select" key to register the set
value.
6. Press the "Clear" key to complete the setting
operation.
7. Press the "Clear" key one more time to return to
"FACTORY MODE".
SM
39 FACTORY MODE
44 LIFE PERIOD
123456 89ABCDEFG
PERIOD BL UNIT ?
PERIOD BL UNIT ?
44 LIFE PERIOD
39 FACTORY MODE
5-11
SERVICE MODE MENU
LIFE PERIOD SET
060000p.
SET
060000p.
SET
23456789ABCDEFG
MARGIN ADJUST/L
G157