5.2.4 FIRMWARE SWITCHES

WSW01 (Dial pulse setting)

Selector
No.
1, 2
Dial pulse generation mode
3, 4
Break time length in pulse dialing
5, 6
Inter-digit pause
Switching between pulse (DP)
7
and tone (PB) dialing by the
function switch
Default dialing mode, pulse (DP)
8
or tone (PB) dialing
Selectors 1 and 2: Dial pulse generation mode
These selectors set the number of pulses to be generated in pulse dialing.
N: Dialing "N" generates "N" pulses. (Dialing "0" generates 10 pulses.)
N + 1: Dialing "N" generates "N + 1" pulses.
10 - N: Dialing "N" generates "10 - N" pulses.
Selectors 3 and 4: Break time length in pulse dialing
These selectors set the break time [A] length in pulse dialing.
(Example: If "1," "2," and "3" are dialed when N is set by selectors 1 and 2.)
[A]
"1"
G157
Function
"2"
5-40
Setting and Specifications
No.
1.
2.
0
0:
N
0
1:
N+1
1
0:
10-N
1
1:
N
No.
3.
4.
0
0:
60 ms
0
1:
67 ms
1
0:
40 ms (for 16 PPS)
1
1:
64 ms (at 106 ms
interval)
No.
5.
6.
0
0:
800 ms
0
1:
850 ms
1
0:
950 ms
1
1:
600 ms
0: Yes
1: No
0: PB
1: DP