MAINTENANCE MODE

WSW18 (Function setting 3)

Selector
No.
1
Not used.
Detection enabled time for CNG
2, 3
and no tone
4, 5
Not used.
6
Registration of station ID
7, 8
Tone sound monitoring
Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset
of the machine, the machine can detect a CNG signal or no tone for the time length
specified by these selectors. The setting specified by these selectors becomes
effective only when selector 8 on WSW20 is set to "1".
Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and
Czech models.
Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the
line.
G157
Function
5-60
Setting and Specifications
No.
2.
3.
0
0:
40 sec.
0
1:
0 sec. (No detection)
1
0:
5 sec.
1
1:
80 sec.
0: Permitted
No.
7.
8.
0
x:
No monitoring
1
0:
Up to phase B at the
calling station only
1
1:
All transmission
phases both at the
calling and called
stations
1: Prohibitted