3.5

Image Quality Adjustment (Scanning Function)

3.5.1
Density adjustment
Adjusts the center density and the variation of density adjustment button.
Original mode
Text/Photo
Photo
845
847
850
852
855
857
860
862
<Procedure>
(1)
While pressing [0] and [5] simultaneously, turn the power ON.
(2)
Key in a code and press the [ENTER] button.
(3)
Key in an adjustment value.
(To correct the keyed-in value, press the [CLEAR] button.)
(4)
Press the [ENTER] button to store the value.
(5)
Turn the power OFF and then back ON to perform scanning job.
(6)
If the desired image density has not been attained, repeat step (2) to (5).
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Item to be adjusted
Text
846
Manual density mode center
value
851
Manual density mode light
step value
856
Manual density mode dark
step value
861
Automatic density mode
3 - 29
06/04
< Adjustment Mode (05) >
Remarks
The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
The larger the value is, the lighter the
light side becomes.
Acceptable values: 0 to 255
The larger the value is, the darker the
dark side becomes.
Acceptable values: 0 to 255
The larger the value is, the darker the
image becomes.
Acceptable values: 0 to 255
e-STUDIO165/167/205/207/237
ADJUSTMENT