2.2

Self-diagnosis Modes

Self-diagnosis Modes
Mode
Adjustment mode
Setting mode
Function setting mode
RAM clear mode
Country/Region mode
Test Modes
Mode
AUTO TEST
INDIVIDUAL TEST
TEST RESULT LIST
FUNCTION TEST
MAINTENANCE
SERVICE LIST
FUNCTION
Note:
Note:
To enter the desired mode, turn ON the power while two digital keys designated to each mode
(e.g. [0] and [5]) are pressed simultaneously.
[0][2]
Country/Region
code
*1 Turn OFF the power after using the self-diagnosis modes, and leave the equipment to the user.
e-STUDIO165/167/205/207/237
ERROR CODE AND SELF-DIAGNOSTIC MODE
For start
[0]+[5]+
Adjusts various items.
[POWER]
[0]+[8]+
Sets various items.
[POWER]
[1]+[3]+
Conducts OPE. PANEL TEST, PRINT TEST, SEN-
[POWER]
SOR TEST, OUTPUT TEST.
[Specified
RAM clear.
keys]+
[POWER]
[0]+[2]+
Country/Region code.
[POWER]
For start
Press the
Use this mode to diagnose the equipment by auto-
[USER FUNC-
matically performing a series of tests.
TIONS] button
Use this mode to perform a test dialogically and
while READY
locate a failure from the test result.
is indicated,
Use this mode to print the results of "AUTO TEST"
and then press
and "INDIVIDUAL TEST".
the [*], [#], [*],
Use this mode to check each function of the equip-
[*] keys.
ment.
Use this mode to perform setups for Memory Clear,
Fax, etc.
Use this mode to Print PROTOCOL TRACE, TOTAL
ERROR, etc.
Use this mode to Print FUNCTION LIST.
[1][3][*]
RAM clear
"INT"
Warming up
"INT" : [INTERRUPT] key on.
Standby
Contents
Contents
[Power]ON
[0][5]
[0][8]
Adjust mode
System mode
"INT"
Test print
Power OFF
Fig. 2-1
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
2 - 4
06/09
For exit
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
[POWER]
OFF/ON
-
For exit
READY:
Press the
[USER
FUNC-
TIONS] but-
ton.
Test Mode
Menu:
Press the [*],
[#], [*], [*]
keys.
[1][3]