Remarks "*" in the Preventive Maintenance Check List
* a1.
Original glass / ADF original glass
Clean both sides of the original glass and ADF original glass.
Make sure that there is no dust after cleaning. Then install the original glass and ADF orig-
inal glass.
Note:
Note:
Make sure that there is no fingerprints or oil staining on part of the original glass on where the
original scale is mounted since the shading correction plate is located below the scale to be
scanned.
* c1.
Drive gears in the paper feeding section (teeth of gears and shafts)
Apply some white grease (Molykote X5-6020) to the teeth of gears and shafts of the drive
gears.
Note:
Note:
Make sure that oil is not running over or scattered around as the gear is rotated coming into the
clutch after applying Molykote to the gear which is located near the clutch. The quantity of
Molykote should be smaller than that to be applied to the other parts.
* f1.
Main charger case / Needle electrode
Clean the main charger case with a cloth soaked in water and squeezed tightly, and then
wipe them with a dry cloth.
Clean the needle electrode only with the main charger cleaner.
Replace the needle electrode with a new one if it is damaged regardless of the number of
output pages which have been mode.
Note:
Note:
Do not touch the needle electrode with your bare hand when attaching the needle electrode.
e-STUDIO165/167/205/207/237
PREVENTIVE MAINTENANCE (PM)
Fig. 4-5 Paper Feed Pedestal (PFP)
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved