Download Print this page

Toshiba e-STUDIO165 Service Manual page 97

Hide thumbs Also See for e-STUDIO165:

Advertisement

Classifi-
Code
cation
1372
Counter
Heater and energizing time
accumulating counter Dis-
play/0 clearing
1378
Counter
Counter for period of time
fuser unit is at ready tem-
perature
1380
Counter
Counter for period of time
fuser unit is at printing tem-
perature
1382
Counter
Counter for period of time
fuser unit is at energy sav-
ing temperature/Counter
reset
1385
Counter
Number of output pages
(Thick paper 1)
1386
Counter
Number of output pages
(Thick paper 2)
1388
Counter
Number of output pages
(OHP film)
1410
Counter
Counter for period of toner
cartridge rotation time
1411
Counter
Counter for envelope
1428
Data
Forcible SRAM backup
overwrite
data all clearing
1440
Network
IP Conflict Detect
1447
Network
IPP administrator name
1448
Network
IPP administrator pass-
word
1449
Network
IPP authentication method
1450
Network
User name for IPP authen-
tication
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Setting mode (08)
Default
Func-
<Accept-
Items
tion
value>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
<8 digits>
ALL
ALL
ALL
ALL
ALL
ALL
2 - 75
RAM
Contents
able
0
M
Counts up the heater
control time accumu-
lated (when power of
the equipment is ON)
but does not count at
the Sleep Mode.
0
M
Counts up the heater
control time accumu-
lated (when the equip-
ment is at ready status).
0
M
Counts up the heater
control time accumu-
lated (during printing).
0
M
Counts up the heater
control time accumu-
lated (when the equip-
ment is in the Energy
Saving Mode).
0
M
Counts up when the
registration sensor is
ON.
0
M
Counts up when the
registration sensor is
ON.
0
M
Counts up when the
registration sensor is
ON.
0
M
Counts up the period of
rotation time of the toner
cartridge.
0
M
Counts up when the
registration sensor is
ON.
-
-
When this code is per-
formed, the equipment
cannot be started up.
1
CTL
OFF/ON
<1-2>
1: Valid
2: Invalid
-
CTL
This should be an
account which can con-
trol all IPP jobs.
-
CTL
This should be the
password of an account
which can control all
IPP jobs.
1
CTL
1: Disabled
<1-4>
2: Basic
3: Digest
4: Basic Digest
-
CTL
This should be the
account at the time IPP
authentication was per-
formed.
e-STUDIO165/167/205/207/237
ERROR CODE AND SELF-DIAGNOSTIC MODE
Proce-
dure
1
2
1
1
1
1
1
1
1
1
5
1
3
3
1
3

Hide quick links:

Advertisement

loading

This manual is also suitable for:

E-studio167E-studio205E-studio207E-studio237