When properly completed
When the update is completed correctly, "Complete" is displayed after each
item.
Fig. 6-41
On an update error
If the update is not completed correctly, "Error" is displayed after each item.
Fig. 6-42
Note:
Note:
IF an error occurs, repeat the procedure from the first step to retry updating.
(12) Turn OFF the power of the equipment, and disconnect the USB cable.
(13) Perform the initialization of the update data.
Turn the power ON while pressing [0] and [8] buttons simultaneously.
Key in "947", and then press the [START] button.
Press the [START] button.
Note:
Note:
After the updating is completed, check each data version in the Setting Mode (08) to confirm that
the data were overwritten properly.
08-900: System firmware ROM version
08-921: FROM internal program version
08-922: Function table data version
08-923: Language data version
e-STUDIO165/167/205/207/237
FIRMWARE UPDATING
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved