6.1.1
PWA-DWNLD-350-JIG
[A] Update procedure
Important:
•
Turn OFF the power before installing and removing the download jig.
•
Do not turn OFF the power during the update. The data could be damaged and not be oper-
ated properly.
•
Ensure that the firmware to be updated is for the intended model.
•
If the firmware for e-STUDIO167/207/237 is updated on e-STUDIO165/205 by mistake, a C94
error message appears when the power is turned OFF and then back ON after the update.
Remember that no error message appears when the firmware for e-STUDIO165/205 is
updated on e-STUDIO167/207/237 by mistake.
<Updating System ROM>
(1)
Write the data to the download jig.
P. 6-7 "6.1.2 Writing the data to the download jig (PWA-DWNLD-350-JIG)"
(2)
Turn OFF the power of the equipment.
(3)
Take off the connector cover.
(4)
Connect the download jig with the connector (CN1) on the MAIN board.
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Connector cover
Fig. 6-4
Connector
Fig. 6-5
6 - 3
07/02
e-STUDIO165/167/205/207/237
FIRMWARE UPDATING
6