Example 1:
Confirm whether the front cover is open or
close. The front cover is equipped with the
24-V ON/OFF switch (Interlock switch) and
the front cover switch. The status of both
switches is 1 when the cover is open, and 0
when it is close. When the status of the one
is 0 and that of the other is 1 as shown in the
example, there is something wrong with
either of these switches.
I6 bit 6 (Interlock switch)
I7 bit 3 (Front cover switch)
© 2006 - 2008 TOSHIBA TEC CORPORATION All rights reserved
Front cover
Open
Close
1
0
1
0
2 - 87
06/09
I6 Bit6
I7 Bit3
Fig. 2-9
e-STUDIO165/167/205/207/237