REP 2.11 Drum Maintenance Camshaft

Parts List on
PL 2.1 Item 11
Removal
1.
Remove the Front Door
(REP
1.1).
2.
Remove the Control Panel Cover
(REP
3.
Remove the Left Side Cover
(REP
4.
Remove the Right Side Cover
(REP
5.
Remove the Drum Maintenance Unit
6.
Remove the Lower Inner Duplex Guide
7.
Remove the Inner Simplex Guide and Pre-Deskew Sensor
8.
Remove the Preheater and Deskew Assembly
9.
Remove the Drum Maintenance Pivot Plate
10. Remove the Process Drive
(REP
4.13).
11. Slide the Camshaft to the right, release the bushing by carefully prying it from the ground
plate, and move the left end of the Camshaft towards the rear of the printer. Next, move
the Camshaft to the right, then lift the Camshaft through the slot while removing it to the
right.
Figure 1 Removing the Drum Maintenance Camshaft
Repairs and Adjustments
REP 2.11
1.5).
1.10).
1.11).
(REP
1.16).
(REP
3.2).
(REP
3.1).
(REP
2.20).
(REP
2.17).
Replacement
NOTE: For additional tips, refer to the
available in the ColorQube 8570/8870 Training materials).
When reinstalling the Camshaft, line up the hole on the bushing with the metal ground plate.
Do not bend the Ground Plate while installing the Camshaft.
When installing the Camshaft, position the flat side of the D-shaped cams towards the rear of
the printer as shown in
Figure
the chassis to put the Head Tilt Gear in home position.
Perform the Printhead Forward to Print Position procedure
ment procedure
(ADJ
1.3) before restoring printer power.
October 2012
4-38
Drum Maintenance Camshaft Installation
CAUTION
2. Align the hole in the white Head Tilt Gear with the arrow on
(ADJ
1.2) and Process Drive Align-
Figure 2 Camshaft Position
Revised, 3rd Revision - Xerox Internal Use Only