Test for bad Jetstack triac. Refer to
the Electrical Troubleshooting section in Chapter 6, General Troubleshooting.
Test for shorts to Earth. Measure the resistance of
should be greater than 2 Megaohms.
Are F2 and the triacs OK and is
hms? (Ensure your DMM is rated to measure high-impedance resistance.)
Y
N
Replace the following components:
Electronics Module
(REP
Printhead Assembly
(REP
Replace the Jetstack Fuse Assembly.
Perform procedures in RAP
99,002, 99,003
Replace the Ink Loader
(REP
1.8). Does the error persist?
Y
N
Troubleshooting complete.
Replace the Power Supply Board
(REP
5.6) (Electronics Module).
Figure 1 Ink Loader Thermistor Test Point
Fault Messages and Codes
99,009 ~ 99,013, 99,015
Checking for Shorted and Leaky Triacs
P/JAC2
Pin 1 to Pin 7. It
P/JAC2
Pin 1 to Pin 7 greater than 2 Megao-
5.1)
2.3)
Jetstack Disconnect.
in
99,015 PEST - Drum Cooling Fan Disconnect
A Drum Cooling Fan error has occurred. The Drum Cooling Fan is not drawing the expected
power from the Power Supply. The following troubleshooting applies to this error.
Table 1 Applicable Fault Code
99,015
PEST - Drum Cooling Fan Disconnect
Initial Actions
Reboot the printer and verify the error persists.
Check the Drum Fan for function.
Check the Drum Fan's wiring connection.
If the problem persists, perform the following procedure.
Troubleshooting Reference
Applicable Parts (Chapter 5 - Parts List)
Drum Cooling Fan,
PL 4.1 Item 12
I/O Board,
PL 5.1 Item 10
Wiring and Plug/Jack References (Chapter 7 - Wiring Data)
Figure
5, I/O Board P/J Locations
Figure
8, I/O Board, Sensors (1 of 2)
Procedure
Upgrade firmware
(Firmware
Upgrade). Reboot the printer. Does the error persist?
Y
N
Troubleshooting complete.
Check the Drum Fan wiring harness connector P/J903. Is
undamaged?
Y
N
Reseat and/or replace the wiring harness.
Check resistance on the wiring harness connector P/J903. Is it open or shorted?
Y
N
Replace the I/O Board
(REP
Replace the Drum Cooling Fan
(REP
Y
N
Troubleshooting complete.
Replace the I/O Board
(REP
5.10).
October 2012
2-74
the
connection
5.10).
4.12). Does the error persist?
Revised, 3rd Revision - Xerox Internal Use Only
ColorQube 8570/8870 Service Manual
secure
and

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Colorqube 8870

Table of Contents