99,071 PEST - Power Dump Circuit Disconnected

A power dump circuit error has occurred. The following troubleshooting procedure applies to
this error.
Table 1 Applicable Fault Code
99,071
PEST - Power Dump Circuit seems to be disconnected.
Initial Actions
Reboot the printer and verify the error persists.
Check the component power connections and harness condition.
If the problem persists, perform the following procedure.
Troubleshooting Reference
Applicable Parts (Chapter 5 - Parts List)
Drum Assembly,
PL 2.1 Item 4
Electronics Module,
PL 5.1 Item 1
Power Control Board,
PL 5.1 Item 8
Cable, AC Heater, Drum, Preheater,
Wiring and Plug/Jack References (Chapter 7 - Wiring Data)
Figure
1, Right Side Wire Routing
Figure
2, Right Side Electronics Module P/J Locations
Figure
7, Drum Heater Load Dump, Motors, Head Maintenance Clutch, Strip Solenoid
Procedure
Check the wiring harness connectors
P/J701
undamaged?
Y
N
Reseat and/or replace the wiring harness.
Unplug the connector
P/J120
and measure resistance on the Drum side. The measurement
should be at 13 ohms. Is it open or shorted?
Y
N
Replace the Power Control Board
(REP
Replace the Drum Assembly
(REP
2.4).
Fault Messages and Codes
99,071
PL 5.1 Item 12
and P/J120. Are the connections secure and
5.6) (Electronics Module).