Rep 5.9 Wave Amplifier - Xerox ColorQube 8570 Service Manual

Hide thumbs Also See for ColorQube 8570:
Table of Contents

Advertisement

REP 5.9 Wave Amplifier

Parts List on
PL 5.1 Item 9
Removal
Disconnect the Power Cord before servicing the printer. Line Voltage present on the
Fuse and Fuse Holder Contacts.
Handle the ribbon cables carefully. Check that each cable is square to the socket and fully
inserted. Damage to the Wave Amplifier could result from improper cable connections.
1.
Remove the Control Panel Cover
(REP
2.
Remove the Left Side Cover
(REP
3.
Remove the Right Side Cover
(REP
4.
Remove the Exit Cover
(REP
1.7).
5.
Remove the Ink Loader
(REP
1.8).
6.
Manually tilt the Printhead Assembly forward
7.
Remove the Funnel Cap
(REP
2.1).
8.
Remove the Jetstack Cap
(REP
2.2).
9.
Remove the Ribbon Cable Retaining Clip.
Figure 1 Removing the Ribbon Cable Retaining Clip
Xerox Internal Use Only - Revised, 3rd Revision
ColorQube 8570/8870 Service Manual
WARNING
CAUTION
1.5).
1.10).
1.11).
(ADJ
1.2).
10. Use the Unlock/Lock tool to unlock the ZIF connector
bly by gently lifting up on the ends of the connector lock as shown in
Figure 2 Printhead Cable Connections
11. Remove the Electronics Module
October 2012
4-93
P/J240
from the Printhead Assem-
Figure
(REP
5.1).
Repairs and Adjustments
2.
REP 5.9