99,042 ~ 99,051 PEST - Power Supply Faults

A Power Supply error has occurred. The following troubleshooting procedure applies to these
errors.
Table 1 Applicable Fault Codes
99,042
PEST - Power Supply +1.0 Over Limit
99,043
PEST - Power Supply +1.0 Under Limit
99,044
PEST - Power Supply +1.2 Over Limit
99,045
PEST - Power Supply +1.2 Under Limit
99,046
PEST - Power Supply +1.8 Over Limit
99,047
PEST - Power Supply +1.8 Under Limit
99,048
PEST - Power Supply +2.5 Over Limit
99,049
PEST - Power Supply +2.5 Under Limit
99,050
PEST - Power Supply +3.3 Over Limit
99,051
PEST - Power Supply +3.3 Under Limit
Initial Actions
Reboot the printer and verify the error persists.
Check the component power connections and harness condition.
If the problem persists, perform the following procedure.
Troubleshooting Reference
Applicable Parts (Chapter 5 - Parts List)
Printhead Assembly,
PL 2.1 Item 3
Electronics Module,
PL 5.1 Item 1
Main Controller Board,
PL 5.1 Item 7
Wiring and Plug/Jack Reference (Chapter 7 - Wiring Data)
Figure
8, Main Controller Board P/J Locations
Procedure
Test the Power Supply. Test voltages at
+1.0 V (pin 10)
+1.2 V (pin 6)
+1.8 V (pin 8)
+2.5 V (pin 14)
+ 3.3 V (Ferrite FL802, see
Figure
Are measurements within +/- 5%?
Y
N
Unplug the Printhead gray data cable and remeasure voltages. Are the voltages within
specification (+/- 5%)?
Y
N
Replace the Electronics Module
Replace the Printhead
(REP
2.3).
Replace the Main Controller Board
(REP
Xerox Internal Use Only - Revised, 3rd Revision
ColorQube 8570/8870 Service Manual
P/J802
(see
Figure
1).
1)
(REP
5.1).
5.6) (Electronics Module).
Figure 1 Test Points on the Main Controller Board
October 2012