20
------------ 20-10 -------------
Fuel Supply System
If the fuel pump does not run:
-
Unbolt cover (below rear seat).
-
Release and unplug 4-pin connector from
flange at fuel tank.
K -
Connect hand-held multimeter (e.g. V.A.G
1526) to the outer contacts of the connector
using adapter cables (e.g. from V.A.G 1594
A).
-
Operate remote control.
Specification: approx. battery voltage
If the specification is not achieved:
-
Determine and rectify open circuit in wiring
according to current flow diagram:
⇒ Current Flow Diagrams, Electrical Fault
Finding and Fitting Locations binder
If the specification is achieved:
-
Use MP 1-227 to unscrew union nut.
-
Check whether the electric cables are con-
nected between flange and fuel pump; test
for continuity, if necessary.
If no open circuit in the wiring can be found:
Fuel pump is faulty.
-
Replace fuel delivery unit
⇒ page 20-5.