• Fill fixer tank.
Be careful not to splash fixer into the developer tank. When filling
tanks without roller racks in place, fill tanks to the line of the drain
tube. Wipe up any spills.
CAUTION:
Be careful not to spill any fixer into the developer when
lifting the racks out of a full tank. Even a very small
amount of fixer will contaminate the developer.
• Fill the developer tank.
Always fill the developer tank after the fixer. This is because the
fixer tank is buffered to take any minor carry over from the devel-
oper tank. Wipe up any spills.
• Insert roller racks.
Set processor to manual start mode. To do this, press MAN START.
This will make it easier to get the worm gears on the drive shaft to
engage properly with the drive gears on the roller racks.
Be careful not to drop racks into the tank. This may cause chem-
istry to overflow into the adjacent tank.
When you finish installing the racks, press MAN START again to de-
activate manual start mode.
• Make sure that all vapor shields are in place.
• Make sure that temperature and speed are set correctly.
• Turn on the processor and let it warm up.
When the "DEV TEMP INCOR" LED is off, the processor is ready to
use.
9–26 • Avantra User Guide