Changing Temperature - AGFA SelectSet Avantra User Manual

Drum laser imagesetter
Table of Contents

Advertisement

Changing Temperature

Follow this procedure to change the developer temperature.
Step 1:
Press DEV TEMP.
• The actual developer temperature appears. For example:
Step 2:
Press PRESET.
• The preset developer temperature appears. For example:
Step 3:
Press plus (+) or minus (-) to change the setting.
Step 4:
Press ENTER to store the setting that appears on the display.
To adjust fixer or dryer temperature, press FIX or DRY instead of DEV
in Step 1.
Range for Developer and Fixer Temp.: 23–43° C.
Range for Dryer Temp.: 30–60° C.
9–14 • Avantra User Guide
DEV TEMP 32 C
DEV SET 32 C