PAPER FEED SECTION

5.7 SIDE REGISTRATION MECHANISM

[D]
[E]
[F]
[A]
[B]
[C]
[F]
The shaft [A] of the fine adjusting dial [B] is threaded. The inside of the sleeve
[C] is also threaded. The sleeve is fixed to the feed table stay [D] through a
bracket [E].
The feed table brackets [F] mounted under the table are fixed on the both
ends of the adjusting dial shaft.
When the fine adjusting dial is turned clockwise and the feed table will move
to the right.