DRUM SECTION

9.5 MASTER FEED CLAMPER CAM ADJUSTMENT

ON= 29 ± 0.5 mm
Purpose: To ensure that the master feed clamper is opened during the master
feed process and is closed during other processes.
1. Remove the drum unit from the machine and open the master eject unit.
2. Remove the rear cover of the machine
3. Access "I/O Check Mode".
Use Output Check mode (SP131) No. 15.
4. Press the Print Start key to energize the master feed clamper solenoid [A].
5. Ensure that the distance between the busing and the edge of the opening
cam [B] is 29 ± 0.5 mm when the master feed clamper solenoid is
energized.
6. If not, loosen the mounting screws [C] and adjust the solenoid position.

CAUTION
Do not turn on the solenoid any longer than 10 seconds.
7. After adjustment, retighten the mounting screws.
SM
[C]
[B]
OFF= less than 25 mm
5-51
[A]
[B]
C226