SERVICE PROGRAM TABLE (I/O CHECK MODE)
6. SERVICE PROGRAM TABLE (I/O CHECK
MODE)
6.1 SERVICE PROGRAM MODE OPERATION
The service program (SP) mode is used to check electrical data, change
modes, or change adjustment values.
Service Program Mode Access Procedure (For Engineers)
All service program modes can be accessed with the following procedures.
1. Press the following keys on the operation panel in the following order:
Method 1:
a) Clear Modes key
b) Clear (C) key
c) Combine 2 Originals key
d) Enter key
Method 2:
a) Turn off the power switch
b) Press the Start key, Stop key, and Clear (C) key simultaneously
c) Turn on the power
2. The following is displayed on the LCD when the SP mode is accessed.
3. Using the number keys, enter the desired SP mode number (listed in the
service program table), then press the Enter (#) key.
NOTE: The SP mode number can be shifted up or down by pressing the
Select Size And Direction ("<" or ">") keys.
4. Follow the "Change Adjustment Values or Modes" procedure on the next
page. To exit the SP mode, press the Clear Modes key. If you entered
the SP mode using Method 2, you can exit the SP mode only by turning
the main switch off then on.