Tech Service Bulletin No. C226 – 002
Page 2 of 2
Confirmation: Detection Check
If a used Master Roll is available (with the black End stripe visible), follow the procedure below:
1.
Place the end stripe of the used Master Roll over the Master End Sensor.
2.
Return the release lever.
3.
Make sure that the roll is contacting the sensor, with the end mark at the center of the sensor, as shown
above. If the position is not correct, change the Master End Sensor Bracket (No. 29 on page 1).
4.
Access SP130 (Input Check Mode) and access 26 (SN: Master End).
5.
Press the Start key and make sure the sensor correctly detects the end mark.