NCU Parameters
Address
Country dial tone reset time
680545
(HIGH)
Country dial tone continuous
680546
tone time
Country dial tone permissible
680547
drop time
680548
Country dial wait interval (LOW)
680549
Country dial wait interval (HIGH)
Time between opening or
68054A
closing the DO relay and
opening the OHDI relay
68054B
Break time for pulse dialing
68054C
Make time for pulse dialing
Time between final OHDI relay
68054D
closure and DO relay opening or
closing
Minimum pause between dialed
68054E
digits (pulse dial mode)
Time waited when a pause is
68054F
entered at the operation panel
680550
DTMF tone on time
D418
Function
138
Unit
680549).
20 ms
See Notes 3, 6 and 8.
1 ms
SP2-103-012 (parameter
11).
See Note 3.
1 ms
SP2-103-013 (parameter
12).
See Note 3.
1 ms
SP2-103-014 (parameter
13).
See Notes 3, 6 and 8.
SP2-103-015 (parameter
1 ms
14).
This parameter is only
valid in Europe.
See Note 3 and 8.
SP2-103-016 (parameter
15).
20 ms
SP2-103-017 (parameter
16). See Note 3.
1 ms
SP2-103-018 (parameter
Remarks
SM