Ricoh D065 Service Manual page 1084

Hide thumbs Also See for D065:
Table of Contents

Advertisement

No
Function
1
0
User selectable
1
1
Always enabled
No
Function
Length of time that RDS is
0
temporarily switched on when
to
bits 6 and 7 of System Switch
7
02 are set to "User selectable"
No
Function
0-2
Not used
Printing dedicated tx
parameters on Quick/Speed
3
Dial Lists
0: Disabled
1: Enabled
4-7
Not used
System Switch 05 - Not used (Do not change the factory settings.)
SM
System Switch 02 (SP No. 1-101-003)
certain time, which is stored in System Switch
03. Note that if an RDS operation takes place,
RDS will not switch off until this time limit has
expired.
(1,1): At any time, an RDS system can access
the machine.
System Switch 03 (SP No. 1-101-004)
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of
System Switch 02 are set to "User selectable".
The default setting is 24 hours.
System Switch 04 (SP No. 1-101-005)
Do not change these settings.
1: Each Quick/Speed dial number on the list is
printed with the dedicated tx parameters (10
bytes each).
The first 10 bytes of data are the programmed
dedicated tx parameters; 34 bytes of data are
printed (the other 24 bytes have no use for
service technicians).
Do not change these settings.
71
Bit Switches - 1
Comments
Comments
Comments
D418

Advertisement

Table of Contents
loading

Table of Contents