Bit Switches - 6
No.
T1 timer adjustment
Bit 1
0
0-1
0
1
1
T4 timer adjustment
Bit 3
0
2-3
0
1
1
T0 timer adjustment
Bit 5
0
4-5
0
1
1
6-7
Not used
D418
IP Fax Switch 08 (SP No. 1-111-009)
Function
Bit 0
0
35 s
1
40 s
0
50 s
1
60 s
Bit 2
0
3 s
1
3.5 s
0
4 s
1
5 s
Bit 4
0
75 s
1
120 s
0
180 s
1
240 s
Comments
Adjusts the T1 timer.
The default is "00" (35 seconds).
Adjust the T4 timer.
The default is "00" (3 seconds).
Adjusts the fail safe timer. This timer sets
the interval between "setup" data
transmission and T.38 phase decision. If
your destination return is late on the
network or G3 fax return is late, adjust the
longer interval timer.
The default is "00" (75 seconds).
Do not change these settings.