Download Print this page

Christie Mirage 2000 User Manual page 94

Hide thumbs Also See for Mirage 2000:

Advertisement

23(5$7,21

0LUDJH 
NOTE: Avoid using a digital source (particularly YUV) for the white field.
G 86( 7+( 6$0( /$03 32:(5
(Power or Intensity). Set all to the same desired setting (default = maximum).
NOTE: Do not try to match the perceived light output at this point.
6WHS  (67$%/,6+ 67$57,1* 32,17 )25 &2/25 $'-8670(17
D (1$%/( 35,0$5< &2/25 $'-8670(17
menu (
checkbox so that primary color controls can be adjusted and applied to the
image. See Figure 3.36.
Note also that enabling Use Primary Color Adjustment also sets Gamma to its
default—no other setting of Gamma is possible with adjusted primary colors.
If at any time you decide not to use or apply the Adjust Primary Colors (CSC)
feature, delete its checkmark—this disables Red Primary, Green Primary and
Blue Primary controls. In addition, full normal adjustment of Gamma is
regained.
E 6(/(&7 $ ´86(5µ &2/25
7(03(5$785( ´8VHU µ
5(&200(1'(' 
Adjust Primary Color (CSC)
menu, select a "User" color
temperature that you will be
defining through your
adjustment of primary colors
on each projector. Choose
any of the four User choices,
but note that User 1 is the
default color temperature
applied if you add a new
source in the future while
Primary Color Adjustment is
8VHU·V 0DQXDO
2. Wait for the 6 values (blacklevels and drives) to stabilize.
3. Delete the checkmark and leave the Input Levels menu. Input
levels are now correct for this source. Switch to the external
white field for the remainder of this procedure.
. Set all projectors to the same Lamp Mode
03:
), enter a checkmark in the Use Primary Color Adjustment
 (QDEOLQJ 3ULPDU\ &RORU $GMXVWPHQW
)LJXUH 
In the
In the Adjust Primary Color (CSC)
)LJXUH  6WDUW :LWK D ´8VHUµ
7HPSHUDWXUH DQG  :KLWH /HYHOV

Advertisement

loading

This manual is also suitable for:

Mirage 5000