WATER RADIATOR CAP CHECK

Check the release pressure of the radiator cap by util-
ising the appropriate tester as follows:
Apply the cap to the tester as indicated and slowly cre-
ate a pressure by activating the tester.
Make sure that the increase in pressure is interrupted
at 110±15 kPa (1.1±0.15 kg/cm
the tester held steady, the pressure is maintained for at
least ten seconds. Substitute the cap if the pressure is
not maintained for ten seconds.
Radiator cap release pressure: 110±15 kPa (1.1±0.15
kg/cm
2
).

DRAINING THE COOLANT

Remove the expansion tank cap (1).
To empty fluid from the cooling system, proceed as fol-
lows:
• Place a collection container underneath the engine;
• Remove the fluid drain screw (2) on the bottom right-
hand side of the engine and the washer;
Cooling system
2
) and check that with