AC Output Check
1.
See
Figure 7-28.
Test AC output.
a.
Locate voltage regulator connector [46] under
sprocket cover. See
ING. Disconnect from alternator stator wiring.
b.
Connect an AC voltmeter across stator sockets 1-2.
c.
Run the engine at 2000 RPM. The AC output should
be 32-40 volts AC. (approximately 16-20 volts per
1000 RPM).
d.
Repeat test across stator sockets 2-3 and 1-3.
2.
Compare test results to specifications.
a.
If the output is below specifications, charging prob-
lem could be a faulty rotor or stator.
b.
If output is good, charging problem might be faulty
regulator/rectifier. Replace as required.
3.
Check the output again as described under
AND VOLTAGE OUTPUT TEST
7.25 SPROCKET COVER WIR-
CURRENT
on
page
7-26.
b0997x7x
Figure 7-27. Check for Stator Resistance