HOME
BREAKOUT BOX
GENERAL
The BREAKOUT BOX (Part No. HD-42682) splices into the
main harness. Used in conjunction with a DVOM, it allows cir-
cuit diagnosis of wiring harness and connections without hav-
ing to probe with sharp objects.
INSTALLATION
1.
See
4.29 ELECTRONIC CONTROL
2.
Depress latches on each side of connectors [10] (black)
and [11] (gray) and detach connectors from the ECM.
3.
See
Figure 4-9.
Attach Breakout Box (2) to black connec-
tor [10].
a.
Attach black connector from Breakout Box to corre-
sponding black ECM connector.
b.
Attach black connector from the wiring harness to
black connector on Breakout Box.
8890a
1.
Breakout box
2.
Breakout box grey and black connections at main harness
3.
Breakout box grey and black connections at ECM
4.
ECM
4-10
2003 Buell XB9S: Fuel System
MODULE.
1
3
4
Figure 4-9. ECM and Breakout Box with Connections
4.
Attach Breakout Box to gray connector [11].
a.
Attach gray connector from Breakout Box to corre-
sponding gray ECM connector.
b.
Attach gray connector from the wiring harness to
gray connector on Breakout Box.
REMOVAL
1.
See
Figure 4-9.
Depress latches on each side of connec-
tors [10] (black) and [11] (gray).
2.
Detach Breakout Box connectors from ECM connectors.
3.
Detach Breakout Box connectors from wiring harness.
4.
Reconnect harness to ECM. See
CONTROL
MODULE.
4.6
4.29 ELECTRONIC