17. Malfunction code
17.5.57
C6751: CCD clamp/gain adjustment failure
Exposure unit
Step
Correct the harness connection between
1
CCDUB and BCRUB if faulty.
Check for possible extraneous light and
2
correct as necessary.
Clean the lens, mirrors, CCD surface, and
3
shading sheet if dirty
Correct reflective mirror of the scanner if
4
faulty, or change scanner.
5
Change BCRUB
6
Change exposure unit
17.5.58
CC151: ROM contents error upon start-up
Step
1
Restart the machine.
2
Check the ROM version.
3
Rewrite the firmware.
4
Change PRCB
368
Relevant parts
Action
Action
Field Service Ver. 2.0 Dec. 2008
CCDU board (CCDUB)
BCRU board (BCRUB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
WIRING DIAGRAM
Control signal
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
—