Forwarding Access Setting - Konica Minolta bizhub C200 Service Manual

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

10. Service Mode
C. Connection Timeout
Functions
• To set the time for the timeout for accessing the server.
Use
• To use when changing the time for the timeout for accessing the server.
Setting/
• The default setting is 60 sec.
Procedure
10.12.3

Forwarding Access Setting

A. Login Name
Functions
• To register the login name for accessing the program server where firmware is to be
Use
Setting/
1. Select [Login Name].
Procedure
2. Enter the login name (up to 64 one-byte characters) on the on-screen keyboard.
B. Password
Functions
• To register the password for accessing the program server where firmware is to be
Use
Setting/
1. Select [New Password].
Procedure
2. Enter the password (up to 64 characters) on the on-screen keyboard, and touch
3. Select [Confirm New Password].
4. Enter the password (up to 64 characters) on the on-screen keyboard again, and
5. Touch [OK].
C. URL
Functions
• To register the address and directory of the program server where the firmware is to
Use
Setting/
1. Select [URL].
Procedure
2. Enter the URL (up to 256 one-byte characters) on the on-screen keyboard.
NOTE
• Enter the URL which format suits the protocol to be used.
D. File Name
Functions
• To register the file name of the firmware data to be downloaded.
Use
Setting/
1. Select [FileName].
Procedure
2. Enter the file name (up to 63 one-byte characters) on the on-screen keyboard.
316
1
stored.
stored.
[OK].
touch [OK].
be stored in URL.
http:// (Host name or IP address)/ directory name or
https:// (Host name or IP address)/directory name.
Field Service Ver. 2.0 Dec. 2008