C0213: Lct Shift Gate Operation Failure; C0214: Lct Shift Failure - Konica Minolta bizhub C200 Service Manual

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

Field Service Ver. 2.0 Dec. 2008
7.2.5

C0213: LCT shift gate operation failure

Division board position sensor (PS14)
Division board position motor (M3)
Step
Check the motor and sensor connectors for
1
proper connection, and correct as neces-
sary.
Check the connector of motor for proper
2
drive coupling, and correct as necessary.
3
PS14 I/O check, sensor check
4
M3 operation check
5
PCCB replacement
7.2.6

C0214: LCT shift failure

Shift motor pulse sensor (PS8)
Shift tray stop sensor (PS11)
Shift tray home sensor (PS12)
Step
Check the sensor connectors for proper
1
connection, and correct as necessary.
2
PS8 I/O check, sensor check
3
PS11 I/O check, sensor check
4
PS12 I/O check, sensor check
5
PCCB replacement
Relevant electrical parts
Action
Relevant electrical parts
Action
PC control board (PCCB)
WIRING DIAGRAM
Control signal
REYB PJ2<B>-1 (ON)
REYB PJ2<B>-2 to 3
PC control board (PCCB)
WIRING DIAGRAM
Control signal
REYB PJ2<A>-3 (ON)
REYB PJ2<A>-7 (ON)
REYB PJ2<A>-8 (ON)
7. Trouble code
Location
(Electrical
components)
PC-405 K-7 to 8
PC-405 K-7
Location
(Electrical
components)
PC-405 K-6
PC-405 K-4
PC-405 K-4
37

Advertisement

Table of Contents
loading