Field Service Ver. 2.5 Jul. 2006
18.3.5
C0211: Bypass Lifting Motion Failure
Bypass Pick-Up Solenoid (SL3)
Bypass Lift Sensor (PC29)
Step
Check the SL3 connector for proper connection and
1
correct as necessary.
2
Check cam position.
3
PC29 I/O check
4
SL3 operation check
5
Change PWB-A
18.3.6
C0701: Manual Paper Size Detection Adjustment Failure
Bypass Paper Size Detection Unit (VR1)
Step
Check the VR1 connector for proper connection and
1
correct as necessary.
2
Readjust the VR1.
3
Replace VR1
4
Change PWB-A
18.3.7
C1080: Exit Option Communication Failure
Main Control Board (PWB-A FN)
Step
Turn OFF the Main Power Switch, wait for 10 sec. or
1
more, and turn ON the Main Power Switch.
Check the PWB-A FN and the PWB-A for proper
2
connection, and correct as necessary.
3
Change PWB-A FN
4
Change PWB-A
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Power Supply Unit (PU1)
Action
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Action
Relevant Electrical Parts
Mechanical Control Board (PWB-A)
Action
18. Malfunction code
WIRING DIAGRAM
Control Signal
-
-
PWB-A PJ12A-11 (ON)
PWB-A PJ12A-5 (ON)
-
WIRING DIAGRAM
Control Signal
-
-
-
-
WIRING DIAGRAM
Control Signal
-
-
-
-
Location
(Electrical
Component)
-
-
M-14
M-13
-
Location
(Electrical
Component)
-
-
-
-
Location
(Electrical
Component)
-
-
-
-
245