Konica Minolta bizhub C200 Service Manual page 282

Hide thumbs Also See for bizhub C200:
Table of Contents

Advertisement

Field Service Ver. 2.0 Dec. 2008
Mode
370
State
Bit
7-0 Additional number of times to retry transmis-
sion (Network function)
Specify additional retrial times after retrying
the number of times specified by the user.
"0" indicates no additional retrial following the
current number of times specified by the user.
Mode
371
State
Bit
7-5 Retry interval for "additional number of times
to retry transmission" (Network function)
1
Binary division
0
Page division
Mode
372
State
Bit
7-0 Specify transmission interval of size-divided
e-mail file data
Default value
Bit
7654 3210
1111 1111
Setting item
Default value
Bit
7654 3210
0100 0000
Setting item
Default value
Bit
7654 3210
0000 1111
Setting item
HEX: FF
Setting value
0
1
0000 0000
0
0000 0001
1
:
1111 1111
255
HEX: 40
Setting value
0
1
000
10 min.
001
15 min.
010
20 min.
011
25 min.
100
30 min.
others
Not available
Sets Yes/No for binary
No
Yes
division during scan to e-
mail.
Sets Yes/No for page divi-
No
Yes
sion during Internet fax (e-
mail), scan to e-mail.
HEX: 0F
Setting value
0
1
0000 0000
Not available
0000 0001
1 sec.
:
0000 1111
15 sec.
:
1111 1111
255 sec.
10. Service Mode
Description
Description
Description
241

Advertisement

Table of Contents
loading

Table of Contents