17. Malfunction code
17.5.35
C3421: Fusing heaters trouble (heating side)
17.5.36
C3423: Fusing heaters trouble (pressurizing side)
Fusing unit
Step
Check the fusing unit for correct installation
1
(whether it is secured in position).
Check the open/close operation of the
2
upper right door.
Check the fusing unit, PRCB and DCPU for
3
proper connection and correct or change
as necessary.
4
Change fusing unit
5
Change PRCB
6
Change DCPU
17.5.37
C3721: Fusing abnormally high temperature detection (heating side)
17.5.38
C3723: Fusing abnormally high temperature detection (pressurizing side)
Fusing unit
Step
Check the fusing unit for correct installation
1
(whether it is secured in position).
Check the open/close operation of the
2
upper right door.
Check the fusing unit, PRCB and DCPU for
3
proper connection and correct or change
as necessary.
4
Change fusing unit
5
Change PRCB
6
Change DCPU
362
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.0 Dec. 2008
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
—
Location (Electri-
cal component)
—
—
—
—
—
—