17. Malfunction code
17.5.35

C3421: Fusing heaters trouble (heating side)

17.5.36

C3423: Fusing heaters trouble (pressurizing side)

Fusing unit
Step
Check the fusing unit for correct installation
1
(whether it is secured in position).
Check the open/close operation of the
2
upper right door.
Check the fusing unit, PRCB and DCPU for
3
proper connection and correct or change
as necessary.
4
Change fusing unit
5
Change PRCB
6
Change DCPU
17.5.37

C3721: Fusing abnormally high temperature detection (heating side)

17.5.38

C3723: Fusing abnormally high temperature detection (pressurizing side)

Fusing unit
Step
Check the fusing unit for correct installation
1
(whether it is secured in position).
Check the open/close operation of the
2
upper right door.
Check the fusing unit, PRCB and DCPU for
3
proper connection and correct or change
as necessary.
4
Change fusing unit
5
Change PRCB
6
Change DCPU
362
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 2.0 Dec. 2008
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
DC power supply (DCPU)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
Location (Electri-
cal component)
Location (Electri-
cal component)

Advertisement

Table of Contents
loading

Table of Contents