Field Service Ver. 2.0 Dec. 2008
[1]
A02EF2C079DA
[1]
A02EF2C080DA
4. Reinstall the stopper [1].
NOTE
• When reinstalling the stopper, use
care so that both ends of the stop-
per will not open but stay parallel as
shown on the left.
Keep using the stopper after once
stretched out may cause uneven
pitch or other image troubles.
5. Reinstall the gear [1].
NOTE
• Make sure that the gear claw is fit
in.
6. Connect the connector and the flat
cable.
NOTE
• Make sure the harness is installed
along with the harness guide.
7. Follow the same procedures to
install all the PH units.
6. Other
61