(3)
Remove 2 screws and take off the cleaning
unit by lifting it up.
Note:
When installing, fit 2 protrusions on the bot-
tom of the cleaning unit into the holes of the
frame securely.
(4)
Remove spring (A) on each end of the oil
roller.
(5)
Take off the oil roller.
(6)
Remove 1 bushing from each side of the oil
roller.
e-STUDIO281c/351c/451c FUSER UNIT / PAPER EXIT SECTION
Bushing
16 - 20
Cleaning unit
Fig.16-13
Spring ( A )
Oil roller
Fig.16-14
Oil roller
Bushing
Fig.16-15