[B-3]
Paper stock sensor (S31/S32)
(1)
Take off the drawer feeding unit (
"[B-1] Drawer feeding unit").
(2)
Pull up the paper stock sensor arm.
(3)
Disconnect the connector and release the
latch to take off the paper stock sensor.
[B-4]
Separation roller
(1)
Take off the drawer feeding unit (
"[B-1] Drawer feeding unit").
(2)
Remove 1 screw and take off the separation
roller holder.
(3)
Detach the lever from the holder and take off
the separation roller with the shaft.
e-STUDIO281c/351c/451c PAPER FEEDING SYSTEM
P.10-19
P.10-19
Separation roller holder
Holder
10 - 20
Paper stock sensor
Sensor arm
Fig.10-38
Fig.10-39
Lever
Separation roller
Fig.10-40