When the paper in the drawer gets short during copying,
The tray-up sensor turned OFF
The tray-up motor turned ON - Tray goes up
Tray-up sensor turned ON
Tray-up motor stopped
Empty sensor turned OFF during the copying in spite of the tray-up sensor is ON
(B) Paper misfeed in bypas
During bypass feeding
Bypass feed clutch (CLT6) is turned ON
Registration sensor (S22) is turned ON
* Registration sensor (S22) is not turned ON in a fixed period of time (E120)
Bypass misfeeding
Bypass misfeed symbol is displayed
The copying operation is disabled.
Solution: The bypass sensor (S35) is turned OFF by removing the paper from the bypass tray.
June 2005 © TOSHIBA TEC
It is judged that there is no paper.
Drawer area of the control panel blinks.
(When the drawer is selected)
The copying operation is stopped.
e-STUDIO281c/351c/451c GENERAL OPERATION
4 - 11