15.5 Disassembly and Replacement

[A]
Image quality sensor (S17) / Image quality sensor shutter solenoid (SOL1)
(1)
Take off the fuser unit (
unit").
(2)
Take off the process unit (
Process unit").
(3)
Release the harness from the harness clamp
and disconnect 2 connectors.
(4)
Remove 2 screws and take off the image
quality sensor holder.
Note:
Insert prongs of sensor holder to the hole of
the plate securely when installing.
(5)
Disconnect 1 connector and remove 2
screws and then take off the image quality
sensor.
(6)
Remove 2 screws and take off the image
quality sensor shutter solenoid.
June 2005 © TOSHIBA TEC
P.16-19 "[A] Fuser
P.11-10 "[B]
15 - 5
Image quality sensor holder
Fig.15-3
Image quality sensor
Fig.15-4
Image quality sensor shutter solenoid
Fig.15-5