SERVICE PROGRAM MODE
1
(Class 1, 2, and 3)
105*
13
Heating: Duplex/Full
⇒
Color
14
Pressure: Idling
⇒
15
Pressure: Ready
16
Pressure: Standby
⇒
27
Heating: OFFSET +
28
Pressure: OFFSET +
29
Heat: OFFSET –
30
Pressure: OFFSET –
106
Temperature Display
1
Heating Roller
2
Pressure Roller
109
Fusing Nip
1
Execute Mode
2
Stop Duration
⇒
905
Pressure Roller Type
1
Pressure Roller Type
920
Exit Full Timer
1
Exit Full Timer
B051/B052
CÓPIA NÃO CONTROLADA
Mode No.
Sets the heating roller temperature for duplex printing
(both sides) in full-color mode.
[120 ~ 190 / 155 / 1°C/step]
Sets the temperature at which the pressure roller starts
idling.
[30 ~ 100 / 10 / 1°C/step]
Sets the temperature at which the pressure roller
becomes ready for printing.
[60 ~ 150 / 65 / 1°C/step]
Sets the pressure roller temperature for the ready
(standby) condition. After the main switch has been
turned on, the machine enters this condition when the
pressure roller temperature reaches the temperature
specified in this SP mode. When the machine is
recovering from energy saver or auto off mode, the
machine becomes ready when both heat and pressure
roller temperatures reach the specified temperature.
Heating roller: SP1-105-3
[60 ~ 150 / 115 / 1°C/step]
Sets the heating roller temperature correction for when
room temperature is 15°C or lower.
[0 ~ 20 / 5 / 1°C/step]
Sets the pressure roller temperature correction for when
room temperature is 15°C or lower.
[0 ~ 20 / 0 / 1°C/step]
Sets the heating roller temperature correction for when
room temperature is 30°C or higher.
[0 ~ 20 / 5 / 1°C/step]
Sets the pressure roller temperature correction for when
room temperature is 30°C or higher.
[0 ~ 20 / 0 / 1°C/step]
Displays the current temperature of the heating and
pressure rollers.
Checks the fusing nip width using an OHP sheet.
• The OHP sheet stops in the fusing unit for the
• The nip width should be 9 ± 0.5 mm at front and rear.
Adjusts the stoppage time for the OHP sheet in the
fusing unit (
[0 ~ 100 / 10 / 1 s/step]
0: 2.1 mm Type (New)
1: 1.5 mm Type (Old)
[10 ~ 60 / 10 / 1 s/step] DFU
CÓPIA NÃO CONTROLADA
Function / [ Setting ]
specified time (
SP1-109-2).
If this requirement is not met, change the fusing unit.
SP1-109-1).
5-6
Rev. 03/2003
SM