Firmware History for B051/B052
Corrects the following:
•
Modified in accordance with the BICU version 1.291:01 modification.
NOTE:
In addition to this main unit controller version, be sure to update the BICU firmware
to Version 1.291:01 or later.
Corrects the following:
•
The Copier sometimes stalls on machines with the optional MLB installed while the
optional FAX unit is storing documents.
Corrects the following:
•
Modified in accordance with the BICU v1.31:01 modification.
NOTE:
In addition to this main unit controller version, be sure to update the BICU firmware
to Version 1.31:01 or later.
⇒
Corrects the following:
•
SC991 (communication error between main controller and HDD) occurs while an image
scanned with the Scanner is being temporarily stored in HDD memory following recovery
from panel-off
Supplementary:
When recovering from low power mode, the HDD sends the Ready condition signal to the
main controller as soon as the HDD is brought on line. Since the HDD is not actually in its
Ready condition, it is unable to receive data from the controller, triggering the SC. With this
firmware, the HDD will send its ready condition signal only after it has fully reached its Ready
status following recovery from low power mode.
•
"Almost empty" is mistakenly displayed when the waste toner bottle reaches the near-full
condition (Czech only).
NOTE:
In addition to this main unit controller version, be sure to update the language
group 1 firmware to version 3.04 or later.
•
SC687 misdetection when printing out a Printer Document Server document with Date
Printing.
•
The date and time for the last time ACC was performed is not displayed on the operation
panel (Korea models).
•
SC990 misdetection when attempting to print out with Electrical Sort without the standard
HDD installed.
•
SC804 misdetection when scanning non-standard paper sizes 217mm to 219mm in
length in ADF mode.
⇒
•
Print job sometimes stalls when printing out a Printer Document Server document with
Date Printing, which is mistakenly displayed as a paper jam on the operation panel.
NOTE:
In addition to this main unit controller version, be sure to update the BICU firmware
to version 1.333:01 or later.
CÓPIA NÃO CONTROLADA
SYMPTOM CORRECTED
low power mode.
CÓPIA NÃO CONTROLADA
FIRMWARE
VERSION
V2.05.1
V2.05.2
V2.06
V2.07.2
Page 22 of 37