6802D3(H) - Number of PSTN-1 CSI characters (Hex)
6802D4(H) - Number of PSTN-2 CSI characters (Hex)
NOTE: If the number of characters is less than the maximum (20 for RTI, 64 for
TTI), add a stop code (FF[H]) after the last character.
6802E0 to 6802E2(H) - PSTN-1 line settings
6802E0
Bits 0 and 1: PSTN access method from behind a PABX.
Bit
1
0
0
0
0
1
1
0
1
1
Bit 2: Telephone line type.
0: PSTN, 1: PABX
Bits 3 and 4: Dialing type.
Bit
4
3
0
0
0
1
1
0
1
1
Bits 4 to 7: Not used
6802E1: PSTN access number for loop start
Access number Hex value to program (BCD)
0
#
9
00
#
99
6802E2
Bit 0: Transmission disabled
0: Tx and Rx, 1: Rx only
Bit 1: Memory Lock reception
0: Enabled, 1: Disabled
Bits 2 to 7: Not used
6802E8 to 6802EA(H) - PSTN-2 line settings
6802F8 to 6802EA(H) - ISDN line settings
680300(H) - ID code (low - Hex)
680301(H) - ID code (high - Hex)
680302(H) - Confidential ID (low - BCD)
680303(H) - Confidential ID (high - BCD)
680304(H) - Memory Lock ID (low - BCD)
680305(H) - Memory Lock ID (high - BCD)
SM
CÓPIA NÃO CONTROLADA
Setting
Loop start
Ground start
Flash start
Not used
Setting
Pulse dialing
Not used
Tone dialing
Not used
F0
#
F9
00
#
99
123