Ricoh B051 Service Manual page 1010

Ricoh mfp service manual
Table of Contents

Advertisement

Rev. 06/2003
Mode No.
3
(Class 1, 2, and 3)
006*
Density Adjustment
1
M/A Correction
2
Highlight Correction
125
Process control/LD: Pre-ACC self-check setting
1
ACC self-check setting
901
LD-POWER
1
LD 1
2
LD 2
910*
Doctor Interval
1
Color
2
Black
3
Job end
920*
Lubrication Cleaning Time
1
Lubrication Cleaning
Time
SM
CÓPIA NÃO CONTROLADA
Select the toner density compensation level for process
control. If prints are not dark enough when making multi-
print jobs, increasing this value ensures that prints will
be darker after the next process control. The default (0)
is for no correction.
SP3-006-1: Use this one if the density of solid areas is
not satisfactory.
SP3-006-2: Use this one if the density of highlight areas
is not satisfactory.
[0 ~ 3 / 0 / 1/step]
• 0: None
• 1: Weak
• 2: Medium
• 3: Strong
The higher the value, the darker the prints will be.
Enables/disables process control execution before ACC.
[0 ~ 1 / 1 / 1/step]
• 0: Disabled
• 1: Enabled
Specifies the LD power. DFU
[0 ∼ 65535 / 716 / 1 /step]
If the number of pages in a job exceeds this number, the
doctor roller rotates in reverse at the end of the job.
[0 ~ 50 / 50 / 1 sheet/step]
• The value indicates how many sheets are output
before the doctor roller is reversed. (Sheet counts are
converted into equivalent A4-LEF sheet counts.)
• The roller is reversed for 16 seconds
• Reversing the roller removes toner blockages.
• The sheet count is reset after reverse rotation.
• The machine waits until the end of the job before
reversing the doctor roller.
• Decrease the value when vertical white lines appear
on prints.
[0 ~ 65535 / 50 / 1 sheet/step]
If at the end of a job, the roller has not been reversed
since more than this number of pages, the roller is
reversed at the end of the job.
[0 ~ 65535 / 20 / 1 sheet/step]
Sets the OPC belt lubrication period. DFU
[0 ~ 100 / 50 / 1%/step]
• When 100 is specified, the OPC belt cleaning clutch is
always on whenever the OPC is turning, so the OPC
gets lubricated. When 50 is specified, the clutch is
only on half the time that the motor is on.
NOTE: Requires BICU Firmware version 1.253:01 and
controller version 2.01.5.
5-23
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE
Function / [ Setting ]
B051/B052

Advertisement

Table of Contents
loading

This manual is also suitable for:

B052Aficio 1224cAficio 1232c

Table of Contents