Ricoh B051 Service Manual page 1183

Ricoh mfp service manual
Table of Contents

Advertisement

Firmware History for B051/B052
Corrects the following:
The "toner cartridge setting error" is sometimes displayed even when the cartridge has
been set correctly. This is due to misdetection of the information on the cartridge memory
chip.
8"x13" SEF is misdetected as A4 SEF in the by-pass tray.
(EU/Asia versions only).
Default settings for the following have been changed (new defaults underlined).
SP1-003-5, -6, -7 (Paper Buckle for By-pass Tray):
SP1-003-5 By-pass: Plain
[-4 ~ 6 / 3 / 1mm /step]
SP1-003-6 By-pass: Thick
[-4 ~ 6 / 0 / 1mm /step]
SP1-003-7 By-pass: OHP
[-4 ~ 6 / 0 / 1mm /step]
Eliminated unnecessary occurrences of SC410 (2nd transfer electric leakage):
SC410 tends to occur frequently when using paper with high moisture content under
high-temperature, high-humidity when the resistance on the paper transfer roller is low.
The roller current was previously lowered for mono-color mode (45% that of full color),
which lowered the resistance and caused frequent occurrences. This version uses the
color mode current for mono-color until job end to eliminate unnecessary occurrences
under the conditions described above.
Default for SP2-803-01 (Charge Cleaning Off time) changed to minimize idling time
during wire cleaning.
. [0 ~ 200 / 10 / 10 seconds/step]
NOTE:
This adjustment was added from version 1.233:01, and the description has been
added to the version 1.233.01 description below (previously missing).
SP modes newly added (listed below).
These SPs have been added to ensure proper (higher) transfer belt cleaning by applying
the following bias voltages at job end (OPC lubrication time):
SP2-400-008: Cleaning Bias LL1: OPC lubrication time
SP2-401-008: Cleaning Bias LL2: OPC lubrication time
SP2-402-008: Cleaning Bias NN1: OPC lubrication time
SP2-403-008: Cleaning Bias NN2: OPC lubrication time
SP2-404-008: Cleaning Bias HH: OPC lubrication time
[0 to 2000/ 1400 / 10 Volt/step]
Minimum value changed for SP2-941-01, -02 (OPC lubrication time).
Minimum increased from 0 to 6:
SP2-941-01: Job End: [6 ~ 30 / 14 / 1 s/step]
SP2-941-02: OPC Lubrication Interval: [6 ~ 60 / 10 / 1 s/step]
NOTE:
Along with this BICU version, be sure to update the main unit controller firmware to
version 2.02 or later.
CÓPIA NÃO CONTROLADA
SYMPTOM CORRECTED
(Previous default: 0)
(Previous default: -2)
(Previous default: -2)
(previous default: 60)
CÓPIA NÃO CONTROLADA
FIRMWARE
VERSION
1.262:01
Page 9 of 37

Advertisement

Table of Contents
loading

This manual is also suitable for:

B052Aficio 1224cAficio 1232c

Table of Contents