BIT SWITCHES
Communication Switch 16
No
FUNCTION
7
G4 Dual communication
0: Enabled
1: Disabled
Communication Switch 17
No
FUNCTION
0
SEP reception
0: Disabled
1: Enabled
1
SUB reception
0: Disabled
1: Enabled
2
PWD reception
0: Disabled
1: Enabled
3-6
Not used
7
Action when there is no box
with an F-code that matches
the received SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Communication Switch 18 - Not used (do not change the settings)
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B
No
FUNCTION
0
Extension access code (0 to 7)
to
to turn V.8 protocol On/Off
7
0: On
1: Off
B502
CÓPIA NÃO CONTROLADA
1: The machine uses only one B channel for
communication. This enables a customer to occupy
another B channel for other purposes such as
internet communication.
0: Polling transmission to another maker's machine
using the SEP (Selective Polling) signal is disabled.
0: Confidential reception to another maker's
machine using the SUB (Sub-address) signal is
disabled.
0: Disables features that require PWD (Password)
signal reception.
Do not change the settings.
Change this setting when the customer requires.
If the PABX does not support V.8/V.34 protocol
procedure, set this bit to "1" to disable V.8.
Example: If "0" is the PSTN access code, set bit 0
to 1. When the machine detects "0" as the first
dialed number, it automatically disables V.8
protocol. (Alternatively, if "3" is the PSTN access
code, set bit 3 to 1.)