Ricoh B051 Service Manual page 1199

Ricoh mfp service manual
Table of Contents

Advertisement

Firmware History for B051/B052
105
15
Pressure: Ready
16
Pressure: Standby
27
Heating: OFFSET +
28
Pressure: OFFSET +
29
Heat: OFFSET –
30
Pressure: OFFSET –
CÓPIA NÃO CONTROLADA
Sets the temperature at which the pressure roller becomes
ready for printing.
[60 ~ 150 / 65 (70) / 1°C/step]
Sets the pressure roller temperature for the ready (standby)
condition. After the main switch has been turned on, the
machine enters this condition when the pressure roller
temperature reaches the temperature specified in this SP mode.
When the machine is recovering from energy saver or auto off
mode, the machine becomes ready when both heat and
pressure roller temperatures reach the specified temperature.
Heating roller: SP1-105-3
[60 ~ 150 / 115 (120) / 1°C/step]
Sets the heating roller temperature correction for when room
temperature is 15°C or lower.
[0 ~ 20 / 5 / 1°C/step]
Sets the pressure roller temperature correction for when room
temperature is 15°C or lower.
[0 ~ 20 / 0 / 1°C/step]
Sets the heating roller temperature correction for when room
temperature is 30°C or higher.
[0 ~ 20 / 5 / 1°C/step]
Sets the pressure roller temperature correction for when room
temperature is 30°C or higher.
[0 ~ 20 / 0 / 1°C/step]
CÓPIA NÃO CONTROLADA