Ricoh B051 Service Manual page 1088

Ricoh mfp service manual
Table of Contents

Advertisement

SERVICE PROGRAM MODE
Mode No.
3
(Class 1, 2, and 3)
002
Process Control
1
LED
2
Bk Out
3
Bk Led Off Out
4
Color Out
5
Color Led Off Out
6
ID Sensor Target
7
ID sensor Out
Adjustment
10
Bk Vg Control
11
Color Vg Control
12
Color Vd Control
13
gamma M
14
gamma C
002
15
gamma Y
16
Gamma K
17
Invariable-M
18
Invariable-C
19
Invariable-Y
20
Invariable-K
21
OPC Target M
22
OPC Target C
23
OPC Target Y
24
OPC Target K
25
Charge V Offset M
26
Charge V Offset C
27
Charge V Offset Y
28
Charge V Offset K
29
ID sensor Target 1M
30
ID sensor Target 1
Color
31
ID sensor Target 1Y
32
ID sensor Target 2M
33
ID sensor Target 2
Colors
34
ID sensor Target 2Y
35
ID sensor Target 2K
36
Color Development
Bias
37
Bk Development Bias
38
Bias Charge
52
Absolute Temperature
53
Previous Temperature
54
Timer Counter
003*
Lubricant Interval
1
Lubricant Interval
B051/B052
CÓPIA NÃO CONTROLADA
DFU
[0 ~ 255 / 150 / 1 /step]
[0 ~ 0xFFFF / 0 / 1 /step]
[0 ~ 0xFFFF / 0 / 1 /step]
[0 ~ 0xFFFF / 0 / 1 /step]
[0 ~ 0xFFFF / 0 / 1 /step]
[0 ~ 5000 / 1500 / 1 /step]
[800 ~ 12000 / 1000 / 1 /step]
[0 ~ 1000 / 250 / 1 /step]
[0 ~ 1000 / 400 / 1 /step]
[0 ~ 1000 / 150 / 1 /step]
[–30000 ~ 30000 / 2000 / 1 /step]
[–30000 ~ 30000 / 2000 / 1 /step]
[–30000 ~ 30000 / 2000 / 1 /step]
[–30000 ~ 30000 / 5000 / 1 /step]
[–3000 ~ 3000 / 150 / 1 /step]
[–3000 ~ 3000 / 150 / 1 /step]
[–3000 ~ 3000 / 150 / 1 /step]
[–3000 ~ 3000 / 0 / 1 /step]
[400 ~ 2000 / 600 / 1 /step]
[400 ~ 2000 / 620 / 1 /step]
[400 ~ 2000 / 570 / 1 /step]
[400 ~ 2000 / 850 / 1 /step]
[100 ~ 600 / 280 / 1 /step]
[100 ~ 600 / 280 / 1 /step]
[100 ~ 600 / 280 / 1 /step]
[100 ~ 600 / 280 / 1 /step]
[0 ~ 5000 / 1400 / 1 /step]
[0 ~ 5000 / 1400 / 1 /step]
[0 ~ 5000 / 1400 / 1 /step]
[0 ~ 1000 / 200 / 1 /step]
[0 ~ 1000 / 200 / 1 /step]
[0 ~ 1000 / 200 / 1 /step]
[0 ~ 2000 / 1200 / 1 /step]
[50 ~ 300 / 100 / 1 /step]
[50 ~ 300 / 50 / 1 /step]
[0 ~ 1000 / 20 / 1 /step]
[0 ~ 200 / 150 / 1 /step]
[0 ~ 100 / 15 / 1 /step]
[0 ~ 5000 / 1440 / 1 /step]
Sets the process control interval.
[0 ~ 1000 / 200 / 10 sheet/step]
0: Disables automatic process control
5-24
CÓPIA NÃO CONTROLADA
Function / [ Setting ]
Rev. 04/2004
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B052Aficio 1224cAficio 1232c