Option Parameters: F

The following settings are made with the option parameters (F parameters): Settings for Option Cards
nPG Option Setup: F1
Parameters for the PG Speed Control Card are shown in the following table.
Param-
eter
Number
Display
PG constant Sets the number of PG (pulse
F1-01
PG Pulses/
Rev
Operation
selection at
PG open
circuit
(PGO)
F1-02
PG Fdbk
Loss Sel
Operation
selection at
overspeed
(OS)
F1-03
PG Over-
speed Sel
* Factory setting for (-E) models is 1024.
-38
5
Name
Description
LCD
generator or encoder) pulses.
Sets the number of pulses
per motor revolution.
Sets the PG disconnection
stopping method.
0: Ramp to stop
(Deceleration stop using
Deceleration Time 1, C1-
02.)
1: Coast to stop
2: Fast stop (Emergency
stop using the
deceleration time in C1-
09.)
3: Continue operation (To
protect the motor or
machinery, do not
normally make this
setting.)
Sets the stopping method
when an overspeed (OS)
fault occurs.
0: Ramp to stop
(Deceleration stop using
Deceleration Time 1, C1-
02.)
1: Coast to stop
2: Fast stop (Emergency
stop using the
deceleration time in C1-
09.)
3: Continue operation (To
protect the motor or
machinery, do not
normally make this
setting.)
Control Methods
Change
during
Setting
Factory
Range
Setting
Opera-
V/f
tion
600
0 to
No
No
*
60000
(1024)
0 to 3
1
No
No
0 to 3
1
No
No
V/f
Register Page
Open
with
Loop
PG
Q
No
380H
6-143
A
No
381H
6-143
A
No
382H
6-143